Numawan

8 January 2008

Préparation de l’infusion – Preparation of the infusion

Filed under: Construction,Coque - Hull,Infusion — numawan @ 06:50
Tags: ,

Toutes les couches de fibre et de mousse ont été posées, mais rien ne les lie vraiment entre elles. Il s’agit maintenant d’injecter de la résine epoxy de manière aussi uniforme que possible entre toutes les couches.

All the layers of fibre and foam have now been placed, but nothing really is holding them together. We must now inject epoxy resin between all the layers as equally spread as possible.

Tout d’abord, des tissus de drainage sont placés au-dessus des strates pour faciliter la circulation de la résine. Ces tissus seront retirés après l’infusion.

First, drainage clothes are placed above the layers to facilitate the flow of the resin. These clothes will be removed after the infusion.

  

Le plastique vert couvre toute la coque et est attaché de manière étanche aux côtés du moule. Deux types de tubes sont attachés à ce plastique vert. Les tubes blancs servent à extraire l’air. Ils sont connectés entre le haut de la coque et des pompes à vide (pas visibles sur ces photos). Les tubes gris servent à injecter la résine: ils sont connectés entre le bas de la coque et des fûts de résine epoxy. Dans une première phase, les tubes d’apport de résine sont coupés pendant que les pompes à vide extraient l’air du sandwich. Conséquence: le plastique vert semble se coller à la coque. L’infusion sous vide peut commencer lorsqu’un vide suffisant a été établi.

The green plastic covers the whole hull and is fixed in an airtight way to the sides of the mold. Two types of the tubes are attached to the green pastic. The white ones are used to extract air. They are connecting the higher points of the hull to vacuum pumps (not visible on these pictures). The gray ones are used to inject the resin: they are connecting the lower points of the hull to barrels of epoxy resin (not visible on these pictures). In a first phase, the resin tubes are shut while the vacuum pumps suck the air out of the sandwich. As a result, the green plastic seems to glue itself to the hull. The infusion can begin once a sufficient vacuum level is reached.

Leave a Comment »

No comments yet.

RSS feed for comments on this post. TrackBack URI

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out /  Change )

Google+ photo

You are commenting using your Google+ account. Log Out /  Change )

Twitter picture

You are commenting using your Twitter account. Log Out /  Change )

Facebook photo

You are commenting using your Facebook account. Log Out /  Change )

Connecting to %s

Blog at WordPress.com.

%d bloggers like this: